Head-to-Head Technical Specification Matrix

Specification New East Solar Energy (Cambodia) CoLtd New East Solar Energy (Cambodia) CoLtd NESE650-78THB-M10WAAREE ENERGIES LIMITED WAAREE ENERGIES LIMITED Bi-68-650
Manufacturer Brand New East Solar Energy (Cambodia) CoLtdWAAREE ENERGIES LIMITED
Model Designation New East Solar Energy (Cambodia) CoLtd NESE650-78THB-M10WAAREE ENERGIES LIMITED Bi-68-650
Rated Power (STC Pnom) 650 Wp650 Wp
Module Efficiency 23.47%21.67%
Cell Technology Mono-c-SiMono-c-Si
Bifacial Architecture MonofacialYes (80% Bifaciality)
Voltage at Pmax (Vmp) 47.30 V37.91 V
Current at Pmax (Imp) 13.75 A17.16 A
Open-Circuit Voltage (Voc) 56.70 V46.09 V
Short-Circuit Current (Isc) 14.51 A17.84 A
Power Temp. Coefficient (mu_Pnom) -0.273 %/°C-0.337 %/°C
Voltage Temp. Coefficient (mu_Voc) -128.6 mV/°C-158.1 mV/°C
Dimensions (L x W) ——
Weight ——
Product Workmanship Warranty 15 Years15 Years
Linear Performance Warranty 30 Years30 Years
Solerz Heuristics Engine

Deterministic Engineering Verdicts: New East Solar Energy (Cambodia) CoLtd New East Solar Energy (Cambodia) CoLtd NESE650-78THB-M10 vs WAAREE ENERGIES LIMITED WAAREE ENERGIES LIMITED Bi-68-650

Cross-evaluating physical semiconductor behavior, thermal coefficients, balance-of-system footprint, and electrical safety under international engineering standards.

Electrical & String Sizing NEC 690.7 Safety

Extreme Cold Voc Surge & Max String Sizing

Under extreme winter design temperatures (-15°C ambient), open-circuit voltage surges by up to 13.7% due to the negative temperature coefficient of silicon PN junctions. Under a standard 1,000V DC system limit, WAAREE ENERGIES LIMITED WAAREE ENERGIES LIMITED Bi-68-650 safely permits 19 modules per string compared to 16 modules for the tighter models, reducing overall DC home-run combiner wiring and balance-of-system cost by up to 15.8%.

Quantitative Metrics:
  • New East Solar Energy (Cambodia) CoLtd NESE650-78THB-M10: 61.8V (16 mods/str)
  • WAAREE ENERGIES LIMITED Bi-68-650: 52.4V (19 mods/str) [Winner]
Engineering Rule: Voc(cold) = Voc_STC + [mu_Voc_mV * (T_cold - 25°C) / 1000]
Thermal Dynamics Thermal Yield

Midday Hot-Climate Power Retention (65°C Cell)

At peak midday summer operation with a cell junction temperature of 65°C (40°C above standard STC 25°C), thermal degradation causes significant output reduction. New East Solar Energy (Cambodia) CoLtd New East Solar Energy (Cambodia) CoLtd NESE650-78THB-M10 maintains 89.1% of its nameplate power (-0.273%/°C) versus 86.5% on less thermally resilient modules. In tropical, desert, or hot rooftop climates (>35°C ambient), this thermal gap accounts for a 2.6% net annual kWh yield variance.

Quantitative Metrics:
  • New East Solar Energy (Cambodia) CoLtd NESE650-78THB-M10: 579W (89.1% left) [Winner]
  • WAAREE ENERGIES LIMITED Bi-68-650: 562.4W (86.5% left)
Engineering Rule: P_hot = P_stc * [1 + (mu_Pnom_% * (T_cell - 25°C) / 100)]
Lifetime Degradation 25-Year LCOE

25-Year Lifecycle Output & LID/LeTID Retention

Accounting for Light-Induced Degradation (LID) and Light-and-elevated-Temperature-Induced Degradation (LeTID), New East Solar Energy (Cambodia) CoLtd New East Solar Energy (Cambodia) CoLtd NESE650-78THB-M10 preserves 84.8% of original rated power at Year 25 (0.55%/yr degradation) compared to 84.8% on conventional models. Over a standard 25-year asset lifecycle for a 10 kW residential array, this creates an incremental generation delta of +0 MWh of clean electricity.

Quantitative Metrics:
  • New East Solar Energy (Cambodia) CoLtd NESE650-78THB-M10: 84.8% (Yr25) / 331.3 MWh
  • WAAREE ENERGIES LIMITED Bi-68-650: 84.8% (Yr25) / 331.3 MWh
Engineering Rule: Yield(Yr25) = 100% - [FirstYearDeg% + 24 * AnnualDeg%]
Bifacial Performance Albedo Harvest

Bifacial Rear-Side Gain over Reflective Substrates

When deployed over reflective substrates (such as light gravel, white TPO commercial membrane roofs, or snow with 35% albedo), rear-side photon absorption provides significant boost. WAAREE ENERGIES LIMITED WAAREE ENERGIES LIMITED Bi-68-650 yields an effective output of 777.4W (+19.6% gain) thanks to a 80% bifaciality factor, providing higher energy density per installed structure.

Quantitative Metrics:
  • New East Solar Energy (Cambodia) CoLtd NESE650-78THB-M10: 650W (+0% rear)
  • WAAREE ENERGIES LIMITED Bi-68-650: 777.4W (+19.6% rear) [Winner]
Engineering Rule: P_effective = P_stc * [1 + (Albedo * BifacialityFactor * ViewFactor)]
Electrical & Cabling I²R Efficiency

DC String Cable Ohm Heating Loss (40m Run)

Due to Joule heating loss ($P = I^2 R$), operating current (Imp) drastically alters DC cable efficiency over a standard 40m array loop ($4\text{ mm}^2$ / 12 AWG copper). New East Solar Energy (Cambodia) CoLtd New East Solar Energy (Cambodia) CoLtd NESE650-78THB-M10 operates at 13.75A, dissipating only 66.2W (1.02% of string power), while high-current alternatives with large 210mm wafers dissipate 103.1W, frequently mandating up-sizing to thicker $6\text{ mm}^2$ or 0\text{ mm}^2$ wiring to prevent thermal throttling.

Quantitative Metrics:
  • New East Solar Energy (Cambodia) CoLtd NESE650-78THB-M10: 66.2W loss (13.75A Imp) [Winner]
  • WAAREE ENERGIES LIMITED Bi-68-650: 103.1W loss (17.16A Imp)
Engineering Rule: P_loss = Imp² * (2 * Length * rho / Area)
Safety & Protection NEC 690.8/9 Code

Maximum Series Fuse & OCPD String Protection

Under NEC 690.8/690.9 overcurrent protection rules, strings require a continuous duty multiplier of .5625 \times I_{sc}$. New East Solar Energy (Cambodia) CoLtd New East Solar Energy (Cambodia) CoLtd NESE650-78THB-M10 draws a lower short-circuit current of 14.51A, qualifying for standard 25A fuses, while high-current modules push OCPD requirements to 30A. Lower fuse ratings lower combiner enclosure thermal buildup and reduce potential arc flash incident energy.

Quantitative Metrics:
  • New East Solar Energy (Cambodia) CoLtd NESE650-78THB-M10: 25A OCPD (Isc: 14.51A) [Winner]
  • WAAREE ENERGIES LIMITED Bi-68-650: 30A OCPD (Isc: 17.84A)
Engineering Rule: Fuse_Rating = Isc * 1.25 (Continuous) * 1.25 (Over-irradiance)
Mechanical & Structural Structural Load

5,400 Pa Heavy Snow/Wind Surface Deflection Force

Under an international standard 5,400 Pa heavy snow/wind load, the aggregate downward force on New East Solar Energy (Cambodia) CoLtd New East Solar Energy (Cambodia) CoLtd NESE650-78THB-M10 is 10800 N (1101 kg equivalent) due to its compact 2 m² footprint. Larger oversized utility format panels endure up to 10800 N, creating severe center-span glass deflection, micro-cracking risks, and mandating 6-clamp mounting profiles.

Quantitative Metrics:
  • New East Solar Energy (Cambodia) CoLtd NESE650-78THB-M10: 10800 N (1101 kg load)
  • WAAREE ENERGIES LIMITED Bi-68-650: 10800 N (1101 kg load)
Engineering Rule: TotalForce (N) = TestPressure (5400 Pa) * SurfaceArea (L * W)
Balance of System (BOS) BOS Cost Optimization

10 kW Array Roof Footprint & Racking BOS Efficiency

To construct a nominal 10 kW DC solar array, New East Solar Energy (Cambodia) CoLtd New East Solar Energy (Cambodia) CoLtd NESE650-78THB-M10 requires only 16 modules occupying 32 m² of roof space. By contrast, lower efficiency models require up to 16 modules (32 m²), directly increasing mounting rail lengths, roof penetration flashings, MLPE optimizers, and installation labor by 0%.

Quantitative Metrics:
  • New East Solar Energy (Cambodia) CoLtd NESE650-78THB-M10: 32 m² (16 panels)
  • WAAREE ENERGIES LIMITED Bi-68-650: 32 m² (16 panels)
Engineering Rule: ArrayArea = Ceil(10kW / Pnom) * (Module_L * Module_W)
Safety & Protection Hot-Spot Immunity

Hot-Spot Thermal Stress & Bypass Diode Partitioning

Under localized partial tree shading or bird droppings, shadowed cells are forced into reverse bias, dissipating power as localized heat. WAAREE ENERGIES LIMITED WAAREE ENERGIES LIMITED Bi-68-650 incorporates a 66 half-cut cell architecture with 3 Schottky bypass diodes, cutting cell-level current in half and reducing resistive dissipation by 75% during partial shading events to prevent EVA encapsulant browning and thermal cell cleavage.

Quantitative Metrics:
  • New East Solar Energy (Cambodia) CoLtd NESE650-78THB-M10: 78 cells / 3 diodes (Full)
  • WAAREE ENERGIES LIMITED Bi-68-650: 66 cells / 3 diodes (Full) [Winner]
Engineering Rule: P_dissipated = (I_string / Branches)² * R_internal * ShadedCells
Irradiance & Diffuse Light Low-Light Yield

Low-Light & Diffuse Irradiance Retention (200 W/m²)

Under overcast skies, dawn, dusk, or diffuse winter light conditions ($200\text{ W/m}^2$), parasitic shunt resistance determines relative efficiency retention. New East Solar Energy (Cambodia) CoLtd New East Solar Energy (Cambodia) CoLtd NESE650-78THB-M10 maintains 93.5% of its rated conversion efficiency (operating at 21.94% under low irradiance) compared to 93.5% for standard cells. Ideal for northern latitudes with high cloud cover frequencies (e.g. Northern Europe, UK, Pacific Northwest).

Quantitative Metrics:
  • New East Solar Energy (Cambodia) CoLtd NESE650-78THB-M10: 93.5% retention (21.94% eff)
  • WAAREE ENERGIES LIMITED Bi-68-650: 93.5% retention (20.26% eff)
Engineering Rule: Eff_relative(200W) = Eff(STC) * [1 - (V_oc_drop + I_shunt_loss)]
Electrical & MLPE Compatibility MLPE Pairing

Microinverter & MLPE DC/AC Clipping Compatibility

Pairing modules with module-level power electronics (MLPE, such as Enphase or Hoymiles microinverters) requires balancing DC/AC clipping ratio and MPPT current limits (typically 12.5A~14A). New East Solar Energy (Cambodia) CoLtd New East Solar Energy (Cambodia) CoLtd NESE650-78THB-M10 pairs with an optimal DC/AC ratio of 1.97 and 13.75A operating current, eliminating thermal clipping bottleneck while maximizing inverter capacity factor.

Quantitative Metrics:
  • New East Solar Energy (Cambodia) CoLtd NESE650-78THB-M10: 1.97x DC/AC (13.75A Imp)
  • WAAREE ENERGIES LIMITED Bi-68-650: 1.97x DC/AC (17.16A Imp)
Engineering Rule: DC/AC_Ratio = P_nom / P_ac_max; Current_Margin = I_mppt_max - I_mp