Certified Inverter Datasheet & Grid Compliance Assessment

Shenzhen Sinexcel Electric Co Ltd PWS1-1725KTL-H-NA-8M1 {690V} (1708.2 kW) Inverter

Sandia simulation models, California Energy Commission (CEC) test results, and MPPT string sizing specifications.

Rated AC Output
1708.18 kW
Continuous active power
Weighted Efficiency
93.44%
CEC / Sandia curve rating
MPPT Voltage Window
1080–1450 V
Max DC limit: 1450V
Architecture
Utility Central Inverter
Grid-Tied Standard

Solerz Inverter Engineering & Sizing Analysis

1. MPPT Voltage Tracking Dynamics & String Boundaries

The Shenzhen Sinexcel Electric Co Ltd PWS1-1725KTL-H-NA-8M1 {690V} incorporates a precision Maximum Power Point Tracking (MPPT) voltage window of 1080V to 1450V DC, paired with an absolute maximum DC input voltage of 1450V. To prevent inverter shutdown or destructive overvoltage damage during cold winter mornings (-15°C to -30°C), array strings must be strictly designed so that the temperature-corrected open-circuit voltage (Voc_cold) does not breach 1450V. Conversely, under hot summer conditions (+65°C cell temperature), string Vmp must remain comfortably above 1080V to avoid low-voltage MPPT clipping.

2. DC/AC Inverter Loading Ratio (ILR Oversizing)

With a rated continuous AC power of 1708.18 kW, this inverter delivers optimal Levelized Cost of Energy (LCOE) when paired with a DC array capacity of 2306.0 kWp (1.30x – 1.35x Inverter Loading Ratio). Oversizing the PV array ensures the inverter operates in its highest efficiency sweet spot during morning and afternoon shoulder hours, while absorbing midday clipping losses that are economically offset by increased total annual kWh production.

3. Grid Compliance & Interconnection Standards

Engineered in compliance with UL 1741 SB / IEEE 1547-2018 standards, the unit supports advanced autonomous grid-support functions, including dynamic Volt-VAR reactive voltage regulation, Volt-Watt overvoltage curtailment, and frequency ride-through. Total Harmonic Current Distortion (THD) is maintained strictly below 3%, preventing harmonic noise injection into local utility distribution transformers.

Electrical Specifications & Operating Parameters
Rated AC Power Output (Paco)1708180 W (1708.18 kW)
Nominal AC Grid Voltage (Vac)690 V
Weighted Conversion Efficiency93.44 %
Maximum DC Input Voltage (Vdcmax)1450 V
MPPT Voltage Tracking Range1080 – 1450 V
Max Continuous Input Current (Idcmax)1406.18 A
Night Tare Loss (Pnt)321.25 W
Storage CouplingDedicated PV Grid-Tie
Browse All Inverters Calculate MPPT Array Matching Inverter IEEE Standards Handbook