Certified Hardware Datasheet & Engineering Analysis

Boviet Solar Technology Co Ltd Boviet Solar Technology Co Ltd BVM8611M-710-H-HC-BF-DG (710W) Solar Panel

Comprehensive technical specifications, single-diode physical parameters, and climate degradation benchmarking.

Rated Power (STC)
710 Wp
Standard Test Conditions
Module Efficiency
24.40%
Aperture surface yield
Temp Coefficient (Pmax)
-0.29%/°C
Thermal power sensitivity
Cell Technology
Mono-c-Si
Bifacial Dual-Glass

Solerz First-Principles Engineering Evaluation

1. Silicon Architecture & Optical Efficiency

The Boviet Solar Technology Co Ltd Boviet Solar Technology Co Ltd BVM8611M-710-H-HC-BF-DG achieves a verified module conversion efficiency of 24.40%, outputting 710W under Standard Test Conditions (1000 W/m², AM 1.5G, 25°C cell temperature). Featuring half-cut cell geometry with multi-busbar (MBB) interconnects, internal resistive series losses (I²R) are reduced by approximately 75% compared to full-cell designs, substantially mitigating hotspot risks under localized partial shading.

2. Thermal Derating & Hot-Climate Performance

Operating with a power temperature coefficient of -0.29%/°C, this module exhibits robust thermal resilience. During peak summer conditions where rooftop ambient air and roof re-radiation drive cell temperatures to 65°C (a +40°C delta over STC), the module will undergo an estimated thermal derating of -11.7%, maintaining an effective output of 627.1W. Ensuring a minimum 100mm standoff ventilation gap above roof decking is strongly recommended to optimize convective heat dissipation.

3. Electrical Stringing & Inverter MPPT Matching

With a nominal Open-Circuit Voltage (Voc) of 48.9V and Maximum Power Current (Imp) of 17.5A, system designers must account for cold-climate voltage surges. In regions where winter ambient temperatures plummet to -15°C, the cold-temperature open-circuit voltage rises to approximately 266.7V per module. In accordance with NEC Article 690.7, strings must be sized to never exceed inverter maximum DC voltage limits: maximum series string size is 17 modules on 1000V DC commercial inverters, or up to 26 modules on 1500V utility-scale systems.

Electrical & Mechanical Specifications (STC)
Rated Maximum Power (Pmax)710 W
Voltage at Pmax (Vmp)40.70 V
Current at Pmax (Imp)17.46 A
Open-Circuit Voltage (Voc)48.93 V
Short-Circuit Current (Isc)18.44 A
Temperature Coeff. of Pmax-0.292 %/°C
Dimensions (L x W)—
Unit Weight—
Warranty15 Yrs Product / 30 Yrs Power
View Global PV Arena Leaderboard Calculate System Energy Yield Engineering Handbook & Standards