Certified Hardware Datasheet & Engineering Analysis

HD HYUNDAI ENERGY SOLUTIONS CO LTD HD HYUNDAI ENERGY SOLUTIONS CO LTD HiN-T650NJ (650W) Solar Panel

Comprehensive technical specifications, single-diode physical parameters, and climate degradation benchmarking.

Rated Power (STC)
650 Wp
Standard Test Conditions
Module Efficiency
23.47%
Aperture surface yield
Temp Coefficient (Pmax)
-0.27%/°C
Thermal power sensitivity
Cell Technology
Mono-c-Si
Monofacial Backsheet

Solerz First-Principles Engineering Evaluation

1. Silicon Architecture & Optical Efficiency

The HD HYUNDAI ENERGY SOLUTIONS CO LTD HD HYUNDAI ENERGY SOLUTIONS CO LTD HiN-T650NJ achieves a verified module conversion efficiency of 23.47%, outputting 650W under Standard Test Conditions (1000 W/m², AM 1.5G, 25°C cell temperature). Featuring half-cut cell geometry with multi-busbar (MBB) interconnects, internal resistive series losses (I²R) are reduced by approximately 75% compared to full-cell designs, substantially mitigating hotspot risks under localized partial shading.

2. Thermal Derating & Hot-Climate Performance

Operating with a power temperature coefficient of -0.27%/°C, this module exhibits robust thermal resilience. During peak summer conditions where rooftop ambient air and roof re-radiation drive cell temperatures to 65°C (a +40°C delta over STC), the module will undergo an estimated thermal derating of -10.9%, maintaining an effective output of 579.0W. Ensuring a minimum 100mm standoff ventilation gap above roof decking is strongly recommended to optimize convective heat dissipation.

3. Electrical Stringing & Inverter MPPT Matching

With a nominal Open-Circuit Voltage (Voc) of 56.7V and Maximum Power Current (Imp) of 13.8A, system designers must account for cold-climate voltage surges. In regions where winter ambient temperatures plummet to -15°C, the cold-temperature open-circuit voltage rises to approximately 348.3V per module. In accordance with NEC Article 690.7, strings must be sized to never exceed inverter maximum DC voltage limits: maximum series string size is 15 modules on 1000V DC commercial inverters, or up to 23 modules on 1500V utility-scale systems.

Electrical & Mechanical Specifications (STC)
Rated Maximum Power (Pmax)650 W
Voltage at Pmax (Vmp)47.30 V
Current at Pmax (Imp)13.75 A
Open-Circuit Voltage (Voc)56.70 V
Short-Circuit Current (Isc)14.51 A
Temperature Coeff. of Pmax-0.273 %/°C
Dimensions (L x W)—
Unit Weight—
Warranty15 Yrs Product / 30 Yrs Power
View Global PV Arena Leaderboard Calculate System Energy Yield Engineering Handbook & Standards